Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Vascular Specialist International ; : 1-2023.
Article in English | WPRIM | ID: wpr-977424

ABSTRACT

Although rare, hepatic artery aneurysms are associated with a high morbidity and mortality, necessitating a prompt diagnosis. A significant proportion of hepatic artery aneurysms are pseudoaneurysms, and the major risk factors of which have already been identified in previous literatures. Presentation can be variable, but diagnosis almost relies entirely on computed tomography and digital subtraction angiography. The endovascular approach has progressively become the preferred option due to its better performance when compared to the traditional surgical approach. However, formulation of an endovascular treatment plan for these lesions remains difficult as multiple factors should be considered to identify the best endovascular treatment modality. Five cases of pseudoaneurysm due to recent Whipple operation, hepatobiliary infections, and underlying malignancy are presented in this article to illustrate the effectiveness and complexity of endovascular treatment in this disease entity.

2.
Neurointervention ; : 11-19, 2017.
Article in English | WPRIM | ID: wpr-730311

ABSTRACT

PURPOSE: A flow diverter (FD) is an effective treatment option for intracranial aneurysms. The Flow Re-direction Endoluminal Device (FRED) is a relatively new flow diverter with a unique dual-layer design. We report our experience and short-term results with the FRED. MATERIALS AND METHODS: We did a retrospective review of all consecutive cases in which the FRED was used to treat intracranial aneurysms at a single institution from March 2014 till December 2015. Clinical parameters, aneurysm characteristics, technical results and short-term outcomes were reviewed. RESULTS: Eleven intracranial aneurysms were treated with the FRED in 11 patients. The technical device deployment success rate was 100%. Immediate reduction in intra-aneurysmal flow after deployment was noted in 10 cases. The aneurysm occlusion rate at 6 months was 75%. There was 1 complication of in-stent thrombosis immediately after deployment. There was no side branch occlusion, delayed aneurysm rupture, stroke, or intraparenchymal haemorrhage. There was no neurological deficit, morbidity, or mortality. CONCLUSION: The FRED is a new FD. It has shown to be safe and effective in our series. The unique dual-layer design of the device renders it to have technical advantages over other FDs. The 6-month aneurysm occlusion rate and complication profile of FRED are similar to other FDs.


Subject(s)
Humans , Aneurysm , Follow-Up Studies , Intracranial Aneurysm , Mortality , Retrospective Studies , Rupture , Stents , Stroke , Thrombosis
SELECTION OF CITATIONS
SEARCH DETAIL